Copeland compressor nomenclature pdf. Discus digital model numbers include additional information about the compressor, consistent with the standard Discus model Emerson provides advanced compressors, condensing units, flow control systems and electronic controls to protect food quality while enabling operators to maximize equipment uptime and increase energy efficiency. compressors, and bulletins AE4-1331 and AE4-1365 for ZPS*K4 compressors. Protect your investment with Copeland DISCUS COMPRESSOR REPLACEMENT GUIDE 2D Discus Nomenclature 3D Discus Nomenclature 4D Discus Nomenclature 6D Discus Nomenclature Model - Displacement + Model - Displacement + Model - Displacement + Model - Displacement + Standard/ Med Temp 2011DS-4 F-Line R1 (11/15)4 Emerson Climate Technologies R-404A Medium/High Temp Copeland Scroll air-cooled condensing units Model Compressor 0 5 10 15 20 25 30 35 40 45 2. note: nominal horsepower rating of compressor UL recognition. •Allow time for the compressor to cool before servicing. 2 (45) 7. In terms of mechanical strength, ZO scroll compressors benefit from many years of experience with R-410A air-conditioning compressors, which operate Exits Compressor Nomenclature The Copeland Discus digital compressor model numbers are designated by a “D” or an “X” in the fourth character, e. ZPV021 ZPV028 ZPV034 ZPV038 ZHV021 ZHV034 Copeland Scroll variable speed compressor nomenclature Z P V 038 Copeland_discus_model_chart. 2°C) evaporating temperature and 130°F (54. use A/C Compressor Product Guide (2008ECT-113) ZPK5 Product Brochure (2004ECT-182 R5) For complete product details and additional information, visit Emerson Climate. The document provides a nomenclature chart for Copeland Discus compressors that explains the codes used to identify key product details like application range, variations, capacity, electrical specifications, and protection features in 3 letters or fewer. Current Discus New Discus Standard 3 1. With scrolls and semi-hermetic compressors available for all main refrigerants, equipped with smart electronics and capable of modulation, Emerson has taken compressor technology to new heights. The compressors lie in the high pressure levels, the higher mass flow for a given displacement, and designing for proper lubrication. It gives details on the compressor specifications, eg, compressor housing version, additional features, IP rating of the electrical box, or associated accessories in the standard delivery. 21. The following overview shows an example of the structure of the nomenclature for a fixed-speed scroll Emerson offers two types of AC drives to be paired with Copeland variable speed 2-15 ton scroll compressors. The BOM (Bill Of Material) number is part of the nomenclature – see example hereunder. Internal Pressure Relief (IPR) Valve WARNING A high pressure control must be used in all applications. com. Use a recovery machine and cylinder 7 Solutions for natural refrigerants 100% Percentage of baseline consumption allowed 2015 2016 - 2017 2018-2020 2021-2023 2024 2025-2026 2027-2029 2030 2031- this endeavor is the newly-designed Copeland Scroll Fusion compressor which combines Emerson’s revolutionary scroll technology along with the serviceability of a traditional semi-hermetic compressor. com and select Online Product Information (OPI) or Copeland Scroll. a external inherent protection. 5 4 4. Copeland ZRK5 Service Compressor Protection kit Copeland Scroll™ ZRK5 Compressor Cross Reference Guide Benefits • Less time searching for the right part • Fewer call-backs with high quality, Copeland certified parts • Inventory reduction and consolidation • Improved troubleshooting speed and accuracy with Comfort Alert diagnostics The Copeland Scroll ™ refrigeration compressor product offering has developed the K5 compressor for the 8 to 15 HP size range. This bulletin describes the operating characteristics, design compressor range (ZR90K* to ZR19M*, ZP180K*) with the new A/C SUMMIT compressor range (ZR94K* to ZR190K* and ZP90K* to ZP182K*, from 7. ZPV021 ZPV028 ZPV034 ZPV038 ZHV021 ZHV034 Copeland Scroll variable speed compressor nomenclature Z 1 2015 Emerson Climate Technologies, Inc. These models will have motor protection through CoreSense technology as well. Both these drives have integrated compressor electronics* technology and RS485 Modbus® communication as a standard. 5 The scroll nomenclature, as given on the nameplate of the compressor, contains information such as compressor model family, application, capacity and other specifications. 5 3 3. 2 Nomenclature The model designation contains the following technical information about the R410A Scroll Compressor Range Broadest Capacity Range Of The Market Copeland Scroll™ ZP R410A compressors for air conditioning and process / precision cooling applications. bulletins and compressor information, please refer to Copeland Mobile. Copeland compressors having an “N” in place of the first digit of the “year” code have been sold without * Units with a compressor RLA under 6A do not require pressure controls for UL listing. 0 ZPV 021 028 034 038 041 ZHV 021 034 ZHV models for hot water heating applications. Specifications (Air-Cooled) K E L. This new range of compressors features a significant size, weight, and sound reduction in all models. Nomenclature Compressor family series C Hermetic Reciprocating Refrigerant R R22,R134a,R407C Capacity XX First two digits of nominal capacity Btu/h @ 60 Hz K x 1,000 multiplier Product family variations 6,7,8 CR Q CR Large Id entifier M Optimized Design Oil type You deserve to be as informed as possible about the products you purchase. Number –270 indicates a standard compressor B/M with crankcase heater. 2 Nomenclature The model designation contains the following technical information about the compressor operating temperatures. g. These application guidelines deal with all vertical single Copeland Scroll compressors for The serial number stamped or printed on the compressor nameplate consists of eight or nine characters. 2. The YP*K1 compressors are qualified with the R32 refrigerant. 8 x 8. 5 HP 8-1347 Copeland PerformanceAlert™ Diagnostic Module 8-1376 Electronic Unit Controller 11-1147 Suction Accumulators 11-1297 Liquid Line Filter-Driers 17-1260 Compressor Overheating A 24-volt DC solenoid valve inside the compressor provides the means to modulate the compressor. 5 5 5. These models of Copeland Scroll compressors do not have internal pressure relief valves. An example would be the ZP20KAE-PFV, which has approximately 20,000 Btu/hr Copeland™ Scroll Compressor, Series: ZPS, 30000 Btu/hr BTU, 3 ton, 3/4 in Stub Suction Line, 1/2 in Stub Discharge Line, 451 - 505 lb/hr, 3. Due to this •M ulti-Compressor Racks 24 • Water-Cooled Condensing Units 28 Compressor Overview 32 • Scroll Compressors 36 • Semi-Hermetic Reciprocating Compressors 42 • Hermetic Integral Horsepower Reciprocating Compressors 46 • Hermetic Fractional Horsepower Re ciprocating Compressors 50 Core Offerings Commercial Air Conditioning These kits are defined by the last digit of the compressor nomenclature’s Bill of Material (BOM). The first two numbers indicate the year of manufacture and the third character, always a letter, designates the month of manufacture. Please refer to product literature for specific model number details. one protector, (line break). This database includes both air conditioning and refrigeration products used in a variety of HVACR applications. 5 to 500kW cooling capacity. CoreSense Protection is noted by a ' C ' in the build of materials, e. 0 8. ) CR Service Compressor Kit Guide UÄj!_ÑáÏ Ï—ð¶1µ þ÷ÀHÀZ˜Ñ–y–Ãk c — ·”” ' Q ë¨æ­+ Ħ« ï¹ÃJ Þfñ™ÏÕ{ÅwmmÛÕ¨mÒ¡Y VóÖÕ‰[à ¼—¼t ¨„ëGC 2w0Tt0{t€8 È "F Á„ ã É•@àÇÀºx6 b °H0ƒc Ó ¦EL LÝL ™ì˜ø ïð âcÜƸ•ñ¨Í Æ“¶ÖVfS W0Öñ ó‹2œf`àócU‚ _ “è ƒ ħ€t8 ëŸÛ@ (¿s ®d`Û6 1. 5T CR18K6-TF5 CR18KQ-TF5 CRA1-0150-TF5 CRA1-0150-TFC CR18K6-TFD CR18KQ-TFD CRA1-0150-TFD 2T CR22K6-TF5 CRC1-0175-TF5 ZR21K5-TF5 CR22K6-TFD ZR21K5-TFD CR24K6-TF5 CR24KQ-TF5 CRD1-0200-TF5 ZR25K5-TF5 scroll compressors outlined in this bulletin range in size from 14,650 Btu/hr to 82,000 Btu/hr (4. The following overview shows an example of the structure of the nomenclature for a fixed-speed scroll Copeland Scroll compressor are described in Figure 1. 800 = std. • The vapor injection technology allows ZFI*KQE compressors to perform higher efficiency than single-stage compressors at low temperature operation condition. 5 - 10. NOTE: The compressor is only one component which must be combined with many others to New Generation Copeland Discus 4D/6D Compressor . pdf - Free download as PDF File (. 5 HP Safety Copeland_discus_model_chart. These reference sheets explain what each letter of the nomenclature means. So homeowners can enjoy its superior cooling power without having to hear its operation. The ZP*K6 compressors include a number of features outlined in the table below. (Premium Service Kits - offered for selected models only. The floatingseal in the compressor effectively acts as a pressure-relief Copeland Scroll Digital compressors have one Scroll compression set driven by a single- or three-phase induction motor. The breadth of our hermetic line means system design engineers can match the right compressor to the job requirement for optimum energy effi ciency. Your local Copeland™ Authorized Wholesaler carries a wide variety of service replacement parts and compressors. The scroll set is mounted at the upper end of the rotor shaft of the motor. 5 2 2. Pay close attention Copeland Scroll compressor nomenclature ZP D 42K 5 E– T F D –130 Z scroll family series AC, R-410A D = Digital S = UltraTech Copeland Discus compressors. Copeland offers the most comprehensive product information in the industry via our online product information (OPI) tool. Nomenclature The model numbers of the Copeland scroll compressors include the approximate nominal 60 Hz capacity at standard operating conditions. •Keep all non-essential personnel away from the compressor during service. 3DSDR17ME-TFD, 4DADF47KE-TSK or 4DJXR28ME-TSK, 6DJXR40ME-TSE. the scroll compressor nomenclature. 3 - 15. Emerson, with our partners, We have 2 Emerson Copeland 3D Series manuals available for free PDF download: Application Manuallines Emerson Copeland 3D Series Application Manuallines (45 pages) Brand: Emerson | Category: Air Compressor | Size: 3. Compressors with PTCs are indicated by an "S" in the second character of the electrical code, e. 4°C) condensing temperature. It is important to ensure correct wiring at both the compressor and drive connections prior to starting the compressor to avoid a mis-wire or powered reverse situation. See Figure 3. 44 x 9. The Copeland Scroll two-stage compressor is remarkably quiet at both full- and part-load capacity. Nomenclature The model numbers of the Copeland scroll compressors include the approximate nominal cooling capacity operating at 60 Hz at standard operating conditions. Signal Word Definitions The signal word explained below are used throughout the document to indicate safety messages. Whether it’s a single-circuit packaged system or a multi- About Copeland 2 Center for World-Class Manufacturing Excellence 4 Copeland Variable Speed Solutions 8 Capacity Range 10 Compressor Dimensions 11 Technical Data 12 Nomenclature 13 Operating Envelopes 14 Variable Speed Drives 16 Integrated Solutions 20 Controllers 22 Control, Valves and Sensors 24 Solution Packages 26 Copelametic™ Compressors 4-1135 Cooling Requirement for Copelametic Compressors 4-1166 Copeland™ Oil Pumps 4-1283 Discus™ R-22 Envelope Extended 4-1287 Copeland Discus™ Demand Cooling 4-1336 Discus™ Optimized Medium Temperature Models Bulletin 8-1275 Sentronic and Sentronic+ Electronic Oil Pressure Control 8-1376 Electronic Unit 2. An example would be the YA460K1E-TED, which has 460,000 Btu/hr (134. Table of Contents Safety Information 04 Features and Benefits 05 Nomenclature 05 Operating Envelopes 06 Technical Data 07 Dimensional Drawings 10 Check that the compressor is properly grounded per the applicable system and compressor requirements. 3. 5 to 12 Copeland Scroll variable speed compressor capacities Model Displacement Tonnage 0. 1. Remove refrigerant from both the high and low side of the compressor. compressor operating temperatures. These application guidelines deal with all vertical single Copeland Scroll compressors for energy and increasing the life of compressor and other system components. 98 MB Mar 16, 2012 · Scroll Compressor Performance Given In This Quick Reference Guide Is At ARI Rating Condition. An example would be Allow time for the compressor to cool before servicing. Scribd is the world's largest social reading and publishing site. It is the most efficient and durable compressor Emerson has ever developed for air conditioning and refrigeration. When the solenoid valve is energized the compressor 7 Solutions for natural refrigerants 100% Percentage of baseline consumption allowed 2015 2016 - 2017 2018-2020 2021-2023 2024 2025-2026 2027-2029 2030 2031- Contact Application Engineering for compressor motor specifications and speed adjustment requirements. For example: A Copeland Discus™ model 6DBNR32M0-TSK-C00 is a standard (non-unloading) Discus III compressor. •Remove refrigerant from both the high and low side of the compressor. pdf), Text File (. 100 = std. Read more about this feature-rich app that is helping contractors perform to their best potential every day. 0 kW) and include common 50 and 60 Hertz, single and three – Table 2: Copeland™ Compressors Family Nomenclature Links The contents of this publication are presented for informational purposes only and are not to be construed as warranties or guarantees, express or implied, compressor will restart once the resistance drops below There are a select few 2D/3D Discus compressors that also use PTC Sensors. CR Series Compressor Nomenclature C R 62 K Q M T F D XXX XX C Series Compressor Compressor Family Series Refrigerant Identifies Code R P Refrigerant R22/R407C/R404A R410A Capacity First Two Digits Of Nominal Compressor Cooling Capacity At 60 Hz Rating Condition Capacity Multiplier K : 1,000 Model Series Variation Arbitrary Number Or Letter Hermetic Compressors – A 2014DS-78 R2 (2/16) 3 Emerson Climate Technologies A F E 10 C 3 E - I A A - 201 Compressor Family Series Either a number or a Set your Compressor and Condensing Unit detailed product information result view: Default (All Collapse) Or select from the list of sections below: Default (none) Summary Performance Components Service Parts Features Accessories Electrical Components Drawings Nomenclature Miscellaneous Bill of Materials Scroll Compressors - Comfort ™• ZR Copeland Scroll Compressor Range for R407C and R134a • ZP Copeland Scroll Compressor Range for R410A • ZP Copeland Scroll Air Conditioning Compressor Range, Optimized for Seasonal Performance • ZPD & ZRD Copeland Scroll Digital™ Compressor Ranges for R410A and R407C Nomenclature Z S I 2 1 K Q E — T F M — 5 3 7 Compressor family Z Copeland Scroll Integrated injection technology Model variation Compressor motor Code Description P T Single-Phase Three-Phase Motor voltage Code Voltage Hz M Z 50 50 380-420V 3Ph 220-240V 1Ph Application range S wide range Copeland Scroll™ Compressors 2-8 Horsepower 4-1387 Application Guidelines for ZS**KAE Copeland Scroll™ Refrigeration Compressors 1. Key features include: Product Specifications for Compressors, Condensing Units, and More; Preliminary and Obsolete Data compressor will have approximately 5/6 of this capacity or 100,000 Btu/hr when operated on 50 Hz power. a subsidàryoflngersoll Rand or Copeland Scroll, a division of Emerson Climate Technobgies Inc. is not affiliated with Trane International, Inc. Offering single compressor R-410A displacements ranging from 3-15 HP and multiple compressor confi gurations up to 30 HP, the Copeland Scroll Digital compressor can be used in a variety of applications. 75 6. scroll motor compressors for the air conditioning, heat pump, and refrigeration markets. The scroll nomenclature, as given on the nameplate of the compressor, contains information such as compressor model family, application, capacity and other specifications. It is the most efficient and durable compressor Emerson has ever developed for air-conditioning and refrigeration. 3PA3R85KL- TFD-C. - Ensure that materials and wiring do not touch high temperature areas of the compressor. March 16, 2012 Temperature ARI Rating ASRE/T Rating Ambient oC ( F) 35 (95) 35 (95) Evaporating oC (oF) 7. Operating Envelope There are various refrigerants that have been approved Copeland Scroll compressor nomenclature ZP D 42K 5 E– T F D –130 Z scroll family series AC, R-410A D = Digital S = UltraTech For additional information, please refer to Copeland Mobile. The motor protector will keep the compressor off till the pressures are equalized. With its unique valve design, grueling life testing and 25 years of field experience, Discus compressors deliver best in class performance. An example would be the YA31K1E-PFV, which has 31,000 Btu/hr (9. Operating Envelope The Copeland Mobile app connects contractors to the Emerson Online Product Information database for on-the-go access to 30 years of Copeland compressor product specifications. 200 = std. ASHRAE Standard 15 and UL 984/60335-2-34 requires a system pressure relief valve when the compressor displacement is greater than 50 CFM. Copeland™ compressors are developed to operate at established maximum load conditions at the extremes of the voltage range, and at light load conditions will operate quite satisfactorily in some cases beyond the established 2. An example would be the ZP236KCE-TED, which has 236,000 Btu/hr (69. Digital Compressor Operation The digital scroll is capable of seamlessly modulating its capacity from 10% to 100%. Emerson Climate Technologies was the first to offer a full R410A line-up of commercial scroll compressors. comp. Use a recovery 4-1299 Application Guidelines for Copeland Scroll Compressors 2 - 6 Horsepower 4-1327 Economized Vapor Injection (EVI) Compressors 4-1387 Application Guidelines for ZS**KAE Copeland Scroll™ Refrigeration Compressors 1. The cover or plug helps to For additional bulletins and compressor information, please refer to Copeland Online Product Information (OPI). • For A3 refrigerants (R290) remove refrigerant from both the high and low sides of the compressor. 3 A, 2980 W, 2-1/4 hp, R-410A, HFC Refrigerant, 3500 rev/min Speed, 70 - 75 dBA, 10. Nomenclature The Copeland Scroll compressor model numbers copelameticâ compressor model number nomenclature compressor cooling code description a air cooled d discus r refrigerant cooled t std. 5 = 7. Copeland™ CR platform reciprocating compressor, sets the industry benchmark for ruggedness and efficiency across the globe. To Get Compressor Performance At ASRE/T Rating, Multiply ARI Capacity And EER Value By 1. 01/0806-0108/E 2/27 Technical Information 2 DWM Copeland Semi-Hermetic S Series Models Capacity Control For 4S, 6S and 8S cylinder compressors a mechanical capacity control is available. 00. Three phase compressors and compressors with high torque start components will start as soon as power is restored. In order to assure that liquid refrigerant does not return to the compressor during the running cycle, attention . To ensure safe operation, a high pressure control must be used in all applications. Nomenclature • M-Line Units Condensing Unit Family Series Hermetic M Temperature Application Code High Temperature Medium Temperature Low Temperature Extended Medium Temp accessory information for Copeland compressors, as well as a quick reference guide, nomenclature breakdowns, common replacement parts and so much more! Operating principles of the Copeland Scroll compressor are described in Figure 7. How It Works A 24-volt DC solenoid valve inside the compressor provides the means to modulate the compressor. View online or download Emerson Copeland D6D Series Compressor Application Manuallines. * Standard and Premium Service Kits are not sold separately, part numbers for reference only. Copeland Scroll variable speed compressor capacities Model Displacement Tonnage 0. An example would be Copeland Scroll Digital compressors have one Scroll compression set driven by a single- or three-phase induction motor. Therefore, the information in this manual relates to Copeland Stream semi-hermetic compressors with standard equipment and The scroll nomenclature, as given on the nameplate of the compressor, contains information such as compressor model family, application, capacity and other specifications. 1 Common information about Copeland™ semi-hermetic compressors This manual covers all Copeland semi-hermetic compressors. Copeland Scroll® Air-Cooled Condensing Units 21-24 Copeland Copevap® Air-Cooled Condensing Units 26-28 Copelametic® Air-Cooled Condensing Units 30-38 Nomenclature Information 39-40 Accessory & Supplemental Information 41-51 ADDITIONAL INFORMATION Form Number Install Confidence With Copeland® Brand Condensing Units 2004DS-166 Compressor mechanical, electrical, and performance data are available online at Copeland Mobile. A greater level of comfort The next generation Copeland Scroll two-stage compressor Copeland Scroll compressor nomenclature example Z P DX 4 2 K 5 E – T F D – 1 3 0 Z Scroll Family Series AC, R-410A DX Nominal Capacity at Rating Condition The scroll nomenclature, as given on the nameplate of the compressor, contains information such as compressor model family, application, capacity and other specifications. These application guidelines deal with all vertical single Copeland Scroll compressors for compressor without start components will stall and trip on motor protector when power is restored. Time Delay: A time delay is not necessary unless a 1. units. Scroll sets engage only after few milliseconds of startup. The scope of this bulletin will cover the application parameters unique to the ZB*K5E and ZF*K5E refrigeration scrolls with CoreSense™ technology. The Copeland Mobile smartphone app provides on-the-go access to Emerson Climate Technologies Online Product Information (OPI) database for Copeland compressor specifi cations. Modular design for ease of fit (separate fi lter and choke) • For use with 2-5 ton variable speed compressors Nomenclature 7 Application Considerations Operating Envelopes 7 The 6-to-15-ton Copeland Scroll compressors do not have internal pressure relief valves. Example: Change HAF*-0025 to HWF*-0025. 5 hp to 4 hp are available as air-cooled or water-cooled versions and use reed valve technology. 3 - 24. 5 - 17 Offset Mounting Rail Horizontal/Vertical Mount View and Download Emerson Copeland Discus Series application manuallines online. 5 6. When the solenoid valve is energized the compressor is in full-load and when de-energized the compressor is in part-load. 12x 8. Other performance data available to the system Copeland Scroll variable speed compressor capacities Model Displacement Tonnage 0. Nomenclature. For additional bulletins and compressor information, please refer to Emerson Online Product Information (OPI). Securely fasten the protective terminal cover or molded plug to the compressor, and 2. 240 volt control. (Reference AE4-1423 for ZPS*K6 and AE4-1365 for ZP*KC for general application requirements and recommendations). 5 21. will dilute the oil in the compressor causing inadequate lubrication and bearing wear. Copeland™ Service CR Compressor Cross Reference Guide Copeland™ Three Phase Compressor Models TONNAGE CR6/5 Ton CRKQ CR7 CR1,2,3 CRKF CRKH ZRK5/K3 1. ZPV021 ZPV028 ZPV034 ZPV038 ZHV021 ZHV034 Copeland Scroll variable speed compressor nomenclature Z compressor operating temperatures. Other drawing formats (IGES, DXF, and STP) can be obtained by contacting your Application Engineer. The semi-hermetic reciprocating compressor family consists of different ranges: The K-Series and L-Series from 0. This allows easier startup of ZB scroll compressors. The BOM (Bill of Material) indication is part of the nomenclature. The following overview shows an example of the structure of the nomenclature for a fixed-speed scroll Com ressor version Short stroke Lon stroke Oil type: — Ester oil 0, 1, Mineral Oil Volt 220 - 230 220 - 240 220 220 - 240 380 - 420 380 - 420 • Allow time for the compressor to cool before servicing. Use a recovery. There are a few important differences outlined below that must be observed when designing a system with the Copeland Scroll UltraTech two step compressor. 801 = std. 5 to 15 HP). Emerson Copeland D6D Series Compressor Pdf User Manuals. 8kWh) cooling capacity CR Series Compressor Nomenclature C R 62 K Q M T F D XXX XX C Series Compressor Compressor Family Series Refrigerant Identifies Code R P Refrigerant R22/R407C/R404A R410A Capacity First Two Digits Of Nominal Compressor Cooling Capacity At 60 Hz Rating Condition Capacity Multiplier K : 1,000 Model Series Variation Arbitrary Number Or Letter Copeland Mobile Copeland™ Mobile App (July 31, 2014) The Copeland Mobile smartphone app provides on-the-go access to Emerson Climate Technologies Online Product Information (OPI) database for Copeland compressor specifi cations. 5 HP 5-1377 Copeland Scroll Outdoor Condensing Unit 5-1412 Copeland Scroll Outdoor Refrigeration Unit of Copeland™ brand products addresses the diverse needs of all of these markets. Copelametic™ Compressors 4-1135 Cooling Requirement for Copelametic Compressors 4-1166 Copeland™ Oil Pumps 4-1283 Discus™ R-22 Envelope Extended 4-1287 Copeland Discus™ Demand Cooling 4-1336 Discus™ Optimized Medium Temperature Models Bulletin 8-1275 Sentronic and Sentronic+ Electronic Oil Pressure Control 8-1376 Electronic Unit project a significant distance from the compressor. From this site, compressor drawings (PDF format) can be downloaded. Nomenclature The model numbers of the Copeland Scroll compressors include the approximate nominal cooling copeland-cf-and-cs-compressor-catalogue. Each compressor has a terminal cover or molded plug that covers electrical connections. 5x 9. Operating Envelope The maximum operating condensing pressure varies for the ZPS*K4 compressors. The capacity range of the QR compressor is 7. This allows the scroll set internal pressures to equalize on compressor stops. Drawing on more than 70 years of experience in designing tough, durable refrigeration compressors, Copeland engineers designed the QR compressor line to meet the demanding requirements it serves. Superheat Requirements . Emerson provides advanced compressors, condensing units, flow control systems and electronic controls to protect food quality while enabling operators to maximize equipment uptime and increase energy efficiency. Nomenclature The Copeland “CS” compressor model numbers include the nominal capacity at the standard ARI 60Hz rating conditions (R404A Refrigerant). AE4-1387 R7 AE4-1387 R7 March 2015 Application Guidelines for ZS**KAE Refrigeration Copeland Scroll™ Compressors 1. Numbers will be assigned as follows: Number –230 indicates a standard compressor B/M and model number. Note that Stream 4M* and 6M* compressors are covered in a different manual see – AGL_Stream_ST_A2L_A1_4M_6M_EN "Copeland™ Stream Semi-Hermetic Compressors". Proper system design will minimize liquid flood back, thereby ensuring maximum compressor life. 2 (45) • Allow time for the compressor to cool before servicing. 55 EER, POE-AK/DA, 3MA/SP32 Compressor Oil, 45-50 deg F Evaporator, 115-130 deg F Condensing, 65-70 deg F Return Gas, 100-115 deg F Compressors with rotalock discharge fittings have a connection on the rotalock fitting for the high pressure cut-out switch connection. Capacities are at 50/115 operating conditions. Use a recovery machine and cylinder designed Nomenclature The model numbers of the Copeland Scroll UltraTech compressors include the approximate nominal 60 Hz capacity at AHRI operating conditions of 45°F (7. This bulletin describes the operating characteristics, design Change "A" in model code to "W" when ordering compressor with water coil. When the ZPS*K6 solenoid is energized a 3-way solenoid valve provides pressure to a lift ring • Allow time for the compressor to cool before servicing. The ZP*KW Copeland Scroll compressors are designed primarily for swimming pool heating and cooling. use compressor and the ZPS*K6 two-stage compressor. The challenges for CO2 compressors compared to HFC compressors lie in the high pressure levels, the higher mass flow for a given displacement, and designing for proper lubrication. xx8 will identify units under 6A that are listed, but do not have pressure controls. 5x 10. An example would be the ZPS49K5E-PFV which has 49,100 Btu/hr (14. Figure 1: Example of nomenclature for a standard Scroll compressor, ZR range this endeavor is the newly-designed Copeland Scroll Fusion compressor which combines Emerson’s revolutionary scroll technology along with the serviceability of a traditional semi-hermetic compressor. 5x 7. D7. Check that the compressor is properly grounded per the applicable system and compressor requirements. Also for: Copeland k series, Copeland l series, Copeland s series, Copeland 2d series, Copeland 3d series, Copeland 8d series, Copeland 6t series, Copeland semi-hermetic compressors are suitable for a wide range of applications in the form of either single compressors, condensing units or as multi-compressor equipment. Bristol Compressors International, Inc. 5 HP 5-1377 Copeland Scroll Outdoor Condensing Unit 5-1412 Copeland Scroll Outdoor Refrigeration Unit The 70 frame ZP*K3 and ZP*KC Copeland Scroll™ compressors are designed for a wide variety of light commercial cooling and heat pump applications. For compressor accessories and service parts, please refer to Emerson Online Product Information (OPI). Copeland Discus Series air compressor pdf manual download. used in copeland cond. Nomenclature The model numbers of Copeland Scroll compressors include the approximate nominal 60 Hz capacity at standard operating conditions. Our compressors are available to support worldwide equipment needs, with many choices of refrigerants and electrical Include the Copeland Scroll Digital compressor in your product offering today. Thus makes ZFI*KQE the best in-class performance. Emerson, with our partners, The scroll sets separate at the instant of compressor shutdown. CO 2 Copeland Discus™ compressors are the leader in the commercial refrigeration industry, combining world-class efficiency and reliability. The rotor shaft axis is in the vertical plane. The Coresense Protection module for Discus compressors combines oil and motor protection into . Please refer to Figure 20for a breakdown of Copeland Digital Nomenclature. and component parts 201 = 201 and larger will be assigned for all other variations. one module, as well as offering optional protection against high discharge temperature and communication compressors, condensing units or as multi-compressor equipment. 5 ZPV 021 028 034 038 ZHV 021 034 ZHV models for hot water heating applications. 1 Common information about Copeland Scroll™ compressors The Scroll compressor has been under development at Emerson since 1979. 3. 0 115 1 60 230 1 60 208-230 1 60 9. replacement compressor and component. The previous generation will be phased out by the end of 2010. Use a recovery Operating principles of the Copeland Scroll compressor are described in Figure 7. 3-4. 120 volt control. 4DH3R22ML-TSK-C00. 7. In terms of mechanical strength, ZO scroll compressors benefit from many years of experience with R-410A air-conditioning compressors, which operate at similar pressure levels as CO 2 compressors. 1 General information about Copeland Scroll™ compressors The Scroll compressor has been under development at Emerson since 1979. The flames can cause serious or fatal burns and ignite nearby materials. Reference the AE4-1430 Compressor Multiples bulletin for multiple compressor applications. 4 kW) Figure 1 – ZPS*K4 Figure 2 – ZPS*K5 These models of Copeland Scroll compressors do not have internal pressure relief valves. 61 cu-ft/min, 208 - 230 VAC, 13. Keep all non-essential personnel away from the compressor during service. two stage w water cooled may be (-) or a model variations a number assigned to indicate major variations within any one family series. Nomenclature The model numbers of the Copeland Scroll compressors include the approximate nominal 60 Hz capacity at standard operating conditions. • Keep all non-essential personnel away from the compressor during service. A normally closed (de- 4-1299 Application Guidelines for Copeland Scroll Compressors 2 - 6 Horsepower 4-1327 Economized Vapor Injection (EVI) Compressors 4-1387 Application Guidelines for ZS**KAE Copeland Scroll™ Refrigeration Compressors 1. Use a recovery machine and cylinder 2. The nomenclature examples below show the 4th character changing for the new Discus models. Due to compressor design changes, UL is requiring that Emerson modify its nomenclature. txt) or view presentation slides online. 8. In fact, it is up to four times quieter than a reciprocating compressor. The Copeland Scroll Fusion compressor features CoreSense™ Diagnostics, which sends and interprets information regarding the compressor’s operation, allowing for quicker, more accurate diagnostics, and less compressor downtime, thus providing more value to its consumers. 5 1 1. 7 Solutions for natural refrigerants 100% Percentage of baseline consumption allowed 2015 2016 - 2017 2018-2020 2021-2023 2024 2025-2026 2027-2029 2030 2031- The voltage extremes at which a compressor will operate depend on the operating load imposed on the compressor. Both situations could potentially cause compressor damage. 5T CR18K6-TF5 CR18KQ-TF5 CRA1-0150-TF5 CRA1-0150-TFC CR18K6-TFD CR18KQ-TFD CRA1-0150-TFD 2T CR22K6-TF5 CRC1-0175-TF5 ZR21K5-TF5 CR22K6-TFD ZR21K5-TFD CR24K6-TF5 CR24KQ-TF5 CRD1-0200-TF5 ZR25K5-TF5 Reference the AE4-1430 Compressor Multiples bulletin for multiple compressor applications. NOTE: The compressor is only one component which must be combined with many others to build a functional and efficient refrigeration system. 1kW) cooling capacity at the AHRI high Copeland™ Service CR Compressor Cross Reference Guide Copeland™ Three Phase Compressor Models TONNAGE CR6/5 Ton CRKQ CR7 CR1,2,3 CRKF CRKH ZRK5/K3 1. 2kW) cooling Copeland hermetic compressors the fi rst choice for every refrigeration need. Features and benefits Compactness • The small footprint of Copeland Scrollcompressors enables compact system designs. Advanced Scroll Temperature Protection (ASTP) A Therm-O-Disc™ temperature-sensitive snap disc provides compressor protection from discharge gas overheating. Figure 1: Example of nomenclature for a standard Scroll compressor, ZR range The YA*K1 scroll compressors are qualified with the R454B refrigerant. Table 1 – Copeland Scroll™ Family 100 = std. The distance depends on the pressure and the amount of refrigerant and oil mixture in the system. In addition to this, the scroll sets are not engaged at the instant of starting. 5x 22. Its scroll technology ex- of Copeland™ brand products addresses the diverse needs of all of these markets. Table of Contents Safety Information 04 Features and Benefits 05 Nomenclature 05 Operating Envelopes 06 Technical Data 07 Dimensional Drawings 10 R410A Copeland Scroll Compressors • AE4-1331 ZP16 to ZP44K3E and ZP14 to ZP61K5E R410a 1/5 to 5 Ton Copeland Scroll Compressors • AE4-1303 7 to 15 Ton ZR*KC and ZP*KC Copeland Scroll Compressors • AE4-1388 20-40 Ton ZP*KC and ZR*KC Copeland Scroll Compressors Compressor assemblies in multiple arrangements are The model number te lls you a lot about a Copeland™ condensing unit. The ZP*KA family includes the features outlined in the matrix below. txt) or read online for free. The 70 frame ZP*K3 and ZP*KC Copeland Scroll™ compressors are designed for a wide variety of light commercial cooling and heat pump applications. In some cases the wholesaler will carry one service replacement model that is capable of replacing several different models. 03, Power Remaining Unchanged. Number –500 series indicates international standard compressor B/M and model number. 5 4. Table 1: 4M* & 6M* compressor range and performance for use with A1 & A2L refrigerants Stream semi-hermetic compressors are suitable for a wide range of applications in the form of either single compressors, refrigeration units or as multi-compressor equipment.